Skip to main content

LG Refrigerator Error Codes

Kitchenaid Refrigerator Error Codes

 Kitchenaid Refrigerator Error Codes

Kitchenaid Refrigerator Error Codes

Label the Components
Label the Components

Defrost System

Automatic defrost after every eight hours of compressor run time is accomplished by utilizing a defrosttimer thermostat in the control box, a defrost bi-metal thermostat attached to the outlet of the evapotatorand a radiant electric heater suspended beneath the evaporator. (Fig. 4)

The bi-metal thermostat is attached to the outlet side of the evaorator coil tubing (Fig. 7) and opens at48°F to terminate the defrost heating. About 33 minutes from the start of the defrost cycle, the timerrestores operation to the compressor circuit. (Fig. 5) The bi-metal thermostat contacts close at 13°F,enabling the defrost heater to operate during the next defrost cycle.

The defrost heater is suspended on the right side and across the bottom of the evaporator. The defrostheater also provides warming to the defrost drain area to keep it clear during the defrost cycle.(Fig.6)

Defrost System
Defrost System

Cleaning

Both the refrigerator and freezer sections defrost automatically. However, clean both sections about once a month to prevent odors from building up. Wipe up spills immediately.

Cleaning your refrigerator

  1. Unplug refrigerator or disconnect power.
  2. Remove all removable parts from inside, such as shelves, crispers, etc.
  3. Hand wash, rinse, and dry removable parts and interior surfaces thoroughly. Use a clean sponge or soft cloth and a mild detergent in warm water.
  4. Wash stainless steel and painted metal exteriors with a clean sponge or soft cloth and a mild detergent in warm water. Do not use abrasive or harsh cleaners. Dry thoroughly with a soft cloth. For additional protection against damage to painted metal exteriors, apply appliance wax (or auto paste wax) with a clean, soft cloth. Do not wax plastic parts.
  5. There is no need for routine condenser cleaning in normal home operating environments. If the environment is particularly greasy or dusty, or there is significant pet traffic in the home, the condenser should be cleaned every two to three months to ensure maximum efficiency.
  6. Plug in refrigerator or reconnect power.

Kitchenaid Refrigerator Troubleshooting

TroublePossible Cause
Operating Sound LevelSee owners manual for explanation of normal operating sound
Freezer Warm - Compressor OffTemperature Control defective or setting too warm
Too Cold in RefrigeratorRefrigerator damper control knob set too cold
Freezer Warm - Compressor Cuts Off on OverloadHeavy usage and/or high ambient
Freezer Too Warm - Compressor OperatingControl knob set too warm
Too Warm in RefrigeratorRefrigerator setting too warm
Freezer Too ColdFreezer temperature control knob set too cold
Long Off Cycle - Too Warm at StartLow ambient temperature
Short off CycleHigh ambient and/or heavy usage
Long or Continuous OperationHeavy usage and/or high ambient
Short Run CycleLow ambient and/or light usage
Condensation on Cabinet ExteriorHigh humidity installation (design accepts bead of water onexterior of cabinet after 4 hours with a 0° to 5°F. (-18° to -17°C.)freezer food temperature and 38° to 40°F. (3°C to 4°C) refrig-erator food temperature in 84% R.H. conditions
No Ice/Low Ice ProductionFreezer not cold enough
Over Production of IceBail shut-off arm not in actuator
Hollow Ice CubesWater fill volume too low
Flooding or Ice Slabs in Bucket or FreezerThermostat out of calibration

Kitchenaid Refrigerator Manual PDF


Popular posts from this blog

Samsung Refrigerator Error Codes

  Samsung Refrigerator Error Codes Samsung Refrigerator Fast Track Troubleshooting: Hold buttons – Freezer, Fridge and Flex Zone for 6 seconds. All on/off LED’s will blink, Stop pressing to view load status. Refer to next. Samsung Refrigerator Display Samsung Refrigerator   Load Mode Part DISPLAY LED Description R-FAN HIGHEST "a" and "b" at the lowest order digit of the R compartment In the case of the R-FAN HIGHEST operation, the corresponding LED is turned on. R-FAN HIGH "a" at the lowest order digit of the R compartment In the case of the R-FAN HIGH operation, the corresponding LED is turned on. R-FAN LOW "b" at the lowest order digit of the R compartment In the case of the R-FAN LOW operation, the corresponding LED is turned on. Overload "e" at the lowest order digit of the R compartment If the external air temperature is 34℃ or higher, the corresponding LED is turned on. Low Temperature "f" at the lowest order digit of th...

LG Refrigerator Error Codes

  LG Refrigerator Error Codes Automatic diagnosis makes servicing the refrigerator easy. When a defect occurs, the buttons will not operate; but the tones. such as ding. will sound. When the defect CODE removes the sign, it returns to normal operation (RESET). The defect CODE shows on the Refrigerator and Freezer Display. LG Refrigerator Control Panel Error Codes Problem and Solution Er - FS Item: Failure of freezer sensor. Contents: Cut or short circuit wire. Remarks: Inspect Connecting wires on each sensor. Er - rS Item: Failure of Refrigerator sensor. Contents: Cut or short circuit wire. Remarks: Inspect Connecting wires on each sensor. Er - dS Item: Failure of defrost sensor. Contents: Cut or short circuit wire. Remarks: Inspect Connecting wires on each sensor. Er - rt Item: Failure of Room Temperature sensor. Contents: Cut or short circuit wire. Remarks: Inspect Connecting wires on each sensor. Er - dH Item: Failure of defrost mode. Contents: When defrost sensor doesn’t reach ...

Siemens Refrigerator Error Codes

  Siemens Refrigerator Error Codes ERROR CODE CAUSE E01 Fridge compartment Sensor break / short circuit E02 Freezer compartment Sensor break / short circuit E06 Fridge evaporator sensor No failure message during normal operation. After auto diagnostic test, E06 is displayed, if evaporator sensor fails E07 Freezer evaporator sensor. No failure message during normal operation. After auto diagnostic test, E07 is displayed, if evaporator sensor fails E15 Ambient Sensor break / short circuit E10 Power module software failure E11 Display module software failure E20 Communication error between power and display module. DOOROPEN When the door remains open for longer 30 s LOWPOWER Not working, until the voltage is above 85 V US / 165 V EU Siemens Refrigerator Free-Standing Series Before you call the after-sales service: Check whether you can rectify the fault yourself by using the notes below. You must bear the costs for consultation with the after-sales services yourself – even during the ...